Title :
Helium Distribution for the Superconducting Devices in NSRRC
Author :
Hsiao, F.Z. ; Li, H.C. ; Chiou, W.S. ; Chang, S.H.
Author_Institution :
National Synchrotron Radiation Research Center, 101 Hsin-Ann Road, Hsinchu 30076, Taiwan
Abstract :
In NSRRC up to five superconducting magnets and one superconducting cavity will be installed in the storage ring. At current stage two superconducting magnets and one superconducting cavity are kept in cold condition by one 450W helium cryogenic system. The crucial stable cryogenic condition required for the superconducting cavity is hard to achieve due to the join of superconducting magnets. A second cryogenic system dedicated for the superconducting magnets is planned in the next stage. A switch valve box serves the function for the backup of two cryogenic systems for each other and a 100 meter nitrogen-shielding helium transfer line dedicated for the five superconducting magnets are installed at end of the year 2004. This paper presents the helium distribution design of the two cryogenic systems and the commission result of the recent work.
Keywords :
Cooling; Cryogenics; Helium; Nitrogen; Refrigeration; Storage rings; Superconducting devices; Superconducting magnets; Switches; Valves;
Conference_Titel :
Particle Accelerator Conference, 2005. PAC 2005. Proceedings of the
Print_ISBN :
0-7803-8859-3
DOI :
10.1109/PAC.2005.1590553