    A slow global orbit feedback (SOFB) is routinely operating in the usual user service operation at PLS. The orbit feedback uses 22 correctors in each plane which have 20-bit capability for the vertical plane and 16-bit capability for the horizontal plane, and the feedback speed is 4 seconds. The orbit stability in RMS was maintained below 1 µ m in both planes for one hour and 3 µ m for a 12-hour operation. The BPM chamber movement due to the change of synchrotron radiation heat load mainly limits the SOFB performance. The intensity dependence of BPM electronics is well compensated by a look-up table of BPM.