DocumentCode :
3198865
Title :
A simple and cast effective solution to reduce motor bearing currents in PWM inverter drives
Author :
Palma, Leonardo ; Moran, Luis ; Wallace, Rogel
Author_Institution :
Dept. of Electr. Eng., Concepcion Univ., Chile
Volume :
2
fYear :
2000
fDate :
2000
Firstpage :
425
Abstract :
High frequency PWM inverters increase the circulation of motor bearing currents due to a high frequency flux induced by common mode currents, which link the stator, rotor and bearing loop. These circulating currents damage the motor bearings, increasing the overall maintenance costs. This paper analyzes the influence of motor design parameters in motor bearing currents amplitude and proposes different alternatives to eliminate them. Among the alternatives proposed in this paper, different types of shunt passive filters, and link reactors are analyzed, and also the influence of the resistance of the rotor bars are studied. Experimental results obtained in a laboratory prototype prove the viability of the theoretical analysis and the effectiveness of the proposed compensating alternatives
Keywords :
AC motors; DC-AC power convertors; PWM invertors; electromagnetic induction; machine bearings; machine testing; machine theory; magnetic flux; rotors; stators; PWM inverter drives; bearing loop; circulating currents; common mode currents; currents amplitude; high frequency flux; high-frequency PWM inverters; link reactors; motor bearing currents reduction; motor design parameters; rotor; rotor bars resistance; shunt passive filters; stator; Bars; Costs; Frequency; Inductors; Laboratories; Passive filters; Pulse width modulation inverters; Rotors; Shunt (electrical); Stators;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Industrial Electronics, 2000. ISIE 2000. Proceedings of the 2000 IEEE International Symposium on
Conference_Location :
Cholula, Puebla
Print_ISBN :
0-7803-6606-9
Type :
conf
DOI :
10.1109/ISIE.2000.930335
Filename :
930335
Link To Document :
بازگشت