DocumentCode :
3198883
Title :
Influence of PLC transmission on the sensitivity of a short-wave receiving station
Author :
Battermann, Sven ; Garbe, Heyno
Author_Institution :
Institut fuer Grundlagen der Elektrotechnik und Messtechnik, Hannover Univ., Germany
fYear :
2005
fDate :
6-8 April 2005
Firstpage :
224
Lastpage :
227
Abstract :
A new application for powerline communication (PLC) is given by a fictive Ethernet connection between two computers based on the home-plug power alliance standard using the mains wiring. This contribution shows the influence on the sensitivity of a real short-wave receiving station by such a PLC transmission in the house. Measurements and numerical calculations have been compared. The reduction of the signal to noise ratio due to the PLC link and the main reasons for the disturbance is shown.
Keywords :
carrier transmission on power lines; local area networks; transport protocols; Ethernet connection; home-plug power alliance standard; powerline communication; real short-wave receiving station; short-wave receiving station; signal to noise ratio; Cables; Conductors; Electromagnetic compatibility; Ethernet networks; Frequency conversion; Interference; Modems; Programmable control; Signal to noise ratio; Wiring;