DocumentCode :
3200288
Title :
Redesign of a Lowenergy Probe Head
Author :
Rao, Y.-N. ; Mackenzie, G.H. ; Ries, T.
Author_Institution :
TRIUMF, Vancouver, Canada
fYear :
2005
fDate :
16-20 May 2005
Firstpage :
1105
Lastpage :
1107
Abstract :
The present situation of the low energy probe LE2 in TRIUMF cyclotron is that the thickness of the finger 5 is uniform over a radial length of 3.25 inch and its weight which amounts to ∼ 447 g is affecting its re-circulating ball mechanism and causing it to fall below the median plane over its range of movement. We therefore re-design it in order to reduce its weight. First, we made simulations and determined the optimum thickness of the probe head vs its radial length. These simulation results are found to be in good agreement with experimental measurements made. Finally, we calculated the temperature rise caused by the beam power dumped on the probe, and figured out the maximum current of beam that can be dumped on the finger.
Keywords :
Copper; Councils; Cyclotrons; Extraterrestrial measurements; Fingers; Numerical simulation; Particle beams; Probes; Protons; Temperature;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Particle Accelerator Conference, 2005. PAC 2005. Proceedings of the
Print_ISBN :
0-7803-8859-3
Type :
conf
DOI :
10.1109/PAC.2005.1590673
Filename :
1590673
Link To Document :
بازگشت