Temperature Regulation of the Accelerating Section in Candle Linac
Author :
Tunyan, S. ; Amatuni, G. ; Grigoryan, B.
Author_Institution :
CANDLE, Yerevan, 375040, Armenia, tunyan@asls.candle.am
fYear :
2005
fDate :
16-20 May 2005
Firstpage :
1416
Lastpage :
1418
Abstract :
The temperature of the CANDLE S-Band Linac high-power Radio Frequency (RF) components will be regulated by Stand-Alone Closed Loop (SACL) water system. The RF components are made of oxygen-free high conductivity copper and respond quickly to temperature changes. Temperature stabilization better than ± 0.1 C is required to achieve a good RF phase and energy stability. The temperature regulation and control philosophy along with the simulation results are discussed.
Keywords :
Acceleration; Control systems; Cooling; Copper; Linear particle accelerator; Radio frequency; Resonant frequency; Stability; Temperature control; Water heating;