DocumentCode
3202814
Title
Protection Level During Extraction, Transfer and Injection into the LHC
Author
Kain, V. ; Goddard, B. ; Schmidt, R. ; Wenninger, J.
Author_Institution
CERN, Geneva, Switzerland
fYear
2005
fDate
16-20 May 2005
Firstpage
1505
Lastpage
1507
Abstract
Failures during the LHC transfer and injection process cannot be excluded and beam loss with the foreseen intensities and energies will cause serious equipment damage. Consequences of equipment failures such as kicker erratics, power converter faults, etc. are investigated by means of a Monte Carlo based on MAD-X tracking with a full aperture model of the transfer line and the injection region. Geometrical and optical mismatch, orbit tolerances, mechanical tolerances for settings of protection elements, power converter ripples, misalignment of elements, etc. are all taken into account. The required performance of the protection system is discussed. The overall protection level for the LHC and the transfer lines during injection is presented.
Keywords
Apertures; Collimators; Equipment failure; Geometrical optics; Large Hadron Collider; Monte Carlo methods; Power system modeling; Power system protection; Protons; Surveillance;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 2005. PAC 2005. Proceedings of the
Print_ISBN
0-7803-8859-3
Type
conf
DOI
10.1109/PAC.2005.1590815
Filename
1590815
Link To Document