Abstract :
Many changes were made to the Z machine oil and water sections in 2007 as part of the Z refurbishment project. As Z was returned to routine operation, some components required modification to increase shot rate. This paper summarizes the oil- and water-section insulator failures encountered in 2008 along with a description of the solutions implemented.
Keywords :
X-ray apparatus; failure analysis; insulators; Sandia National Laboratories; Z machine; high voltage insulator; oil-section insulator failure; water-section insulator failure; Laboratories; Oil insulation; Petroleum; Voltage;