DocumentCode :
3204225
Title :
Magnetic Measurement System for the NSLS Superconducting Undulator Vertical Test Facility
Author :
Harder, D. ; Chouhan, S. ; Lehecka, M. ; Rakowsky, G. ; Skaritka, J. ; Tanabe, T.
Author_Institution :
NSLS@BNL, Upton, NY 11973, USA, dharder@bnl.gov
fYear :
2005
fDate :
16-20 May 2005
Firstpage :
1730
Lastpage :
1732
Abstract :
One of the challenges of small-gap superconducting undulators is measurement of magnetic fields within the cold bore to characterize the device performance and to determine magnetic field errors for correction or shimming, as is done for room-temperature undulators. Both detailed field maps and integrated field measurements are required. This paper describes a 6-element, cryogenic Hall probe field mapper for the NSLS superconducting undulator Vertical Test Facility (VTF) [1]. The probe is designed to work in an aperture only 3 mm high. A pulsed-wire insert is also being developed, for visualization of the trajectory, for locating steering errors and for determining integrated multi-pole errors. The pulsed-wire insert is interchangeable with the Hall probe mapper. The VTF and the magnetic measurement systems can accommodate undulators up to 0.4 m in length.
Keywords :
Apertures; Boring; Cryogenics; Error correction; Hall effect devices; Magnetic field measurement; Magnetic variables measurement; Probes; Test facilities; Undulators;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Particle Accelerator Conference, 2005. PAC 2005. Proceedings of the
Print_ISBN :
0-7803-8859-3
Type :
conf
DOI :
10.1109/PAC.2005.1590893
Filename :
1590893
Link To Document :
بازگشت