Abstract :
The photovoltaic (PV) array on the roof of the Georgia Tech Aquatic Center (USA) is unique in that it is curved, following the curvature of the roof of the Center. This curvature leads to some power loss in the system due to the difference in irradiance over the area of the array, as well as difficulties in obtaining the system efficiency from measured data. These problems could become increasingly common as more PV arrays are integrated into building structures. This paper describes a simple method of overcoming these difficulties using a “curvature derating factor”. First, the parameter is defined. Model calculations are then employed to obtain an estimate of the parameter´s value for a particular system. Finally, an experimental estimation of the parameter is described, and its results are compared with the predictions
Keywords :
losses; photovoltaic power systems; solar cell arrays; PV power system; building-integrated solar arrays; curvature derating factor; curved PV arrays; model calculations; photovoltaic array; power loss; Algorithm design and analysis; Area measurement; Equations; Parameter estimation; Photovoltaic systems; Power engineering and energy; Power engineering computing; Power measurement; Solar power generation; Temperature;
Conference_Titel :
Photovoltaic Specialists Conference, 1997., Conference Record of the Twenty-Sixth IEEE
Conference_Location :
Anaheim, CA
Print_ISBN :
0-7803-3767-0
DOI :
10.1109/PVSC.1997.654326