DocumentCode :
3205563
Title :
Considerations on Beam Quality Control in MIT X-Ray FEL
Author :
Wang, D. ; Graves, W. ; Wang, D.F. ; Zwart, T. ; Emma, P. ; Wu, J. ; Huang, G.
Author_Institution :
Bates Laboratory, MIT, Middleton, MA 01949
fYear :
2005
fDate :
16-20 May 2005
Firstpage :
1961
Lastpage :
1963
Abstract :
The x-ray FEL at MIT[1] is one example of a design for a new generation linac-based light source. Such a new machine requires very high quality electron beams. Besides the usual requirements on beam parameters such as emittance, energy spread, peak current, there are new challenges emerging in the design studies, e.g., the arrival timing of electron beam must reach precision below tens of femtoseconds level to ensure the laser seed overlaps the desired sections of electron bunch in the multiple-stage HGHG process. In this paper we report the progress on design optimization towards high quality and low sensitivity beams.
Keywords :
Electron beams; Laser beams; Linear particle accelerator; Optical design; Optical pulse generation; Optical pulses; Pump lasers; Quality control; Timing; X-ray lasers;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Particle Accelerator Conference, 2005. PAC 2005. Proceedings of the
Print_ISBN :
0-7803-8859-3
Type :
conf
DOI :
10.1109/PAC.2005.1590973