• DocumentCode
    3205929
  • Title

    Analysis of gunshot residue deposited on cloth target

  • Author

    Halim, Mohamed Izzharif Abdul ; Ahmad, Umi Kalthom ; Hooi, Yew Chong ; Jasmani, Halila

  • Author_Institution
    School of Chemistry and Environmental Studies, Faculty of Applied Sciences, Universiti Teknologi Mara, 40450, Shah Alam, Selangor, Malaysia
  • fYear
    2010
  • fDate
    5-7 Dec. 2010
  • Firstpage
    1212
  • Lastpage
    1217
  • Abstract
    The study of gunshot residue (GSR) has become imperative in forensic firearm examination. It may be used to estimate firing distance, to identify bullet holes and to determine whether or not a person has discharged a firearm. This study emphasized on the examination of the pattern of GSR particles deposited on cotton cloth target at different shooting distances (3 inch-12 inch). Two types of pistol (semiautomatic and revolver) and ammunitions (Syarikat Malaysia Explosive (SME) and Winchester) were used for the shooting test. All shooting tests were performed at Lapang Sasar of Pasukan Gerakan Am PDRM, Cheras. The results showed that GSR particles produced on cotton cloth by semiautomatic pistol using SME 9 mm ammunition generated higher amount and larger GSR particles which were almost completely burnt particles. The nitrite residues were confirmed by using modified Griess test that revealed semiautomatic pistol produced considerable amount of nitrite residues. Scanning Electron Microscope (SEM) micrograph of GSR particles discharged from semiautomatic pistol using SME 9 mm ammunition revealed a mean particle size of 2.6 µm with spherical shapes. On the other hand, by using revolver pistol with SME 0.38 Special ammunition, the GSR particles produced were small in amount. The modified Griess test also revealed that revolver pistol generated tiny amount of nitrite residues. Nevertheless, by using Winchester 0.38 Special ammunition, the GSR particles discharge were of high amount and large in size which composed of completely unburned, partially burnt and completely burnt particles. Whereas SEM micrograph of GSR particles discharged from revolver pistol using Winchester 0.38 Special ammunition generated irregular cluster grain with a mean diameter of 3.3 µm. Sodium rhodizonate test was successfully applied for detecting the presence of lead residues around the bullet hole for both pistols.
  • Keywords
    Chemicals; Cotton; Fires; Firing; Lead; Scanning electron microscopy; Gunshot residue; Modified Griess Test; Scanning Electron Microscope; Sodium Rhodizonate Test;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Science and Social Research (CSSR), 2010 International Conference on
  • Conference_Location
    Kuala Lumpur, Malaysia
  • Print_ISBN
    978-1-4244-8987-9
  • Type

    conf

  • DOI
    10.1109/CSSR.2010.5773720
  • Filename
    5773720