Title :
Performance of an Adjustable Strength Permanent Magnet Quadrupole
Author :
Gottschalk, Stephen C. ; Kangas, Kenneth ; DeHart, Terence Ellis ; Volk, James T. ; Spencer, Cherrill M.
Author_Institution :
STI, Washington, scg@stioptronics.com
Abstract :
An adjustable strength permanent magnet quadrupole suitable for use in Next Linear Collider has been built and tested. The pole length is 42cm, aperture diameter 13mm, peak pole tip strength 1.03Tesla and peak integrated gradient length (GL) is 68.7 Tesla. This paper describes measurements of strength, magnetic CL and field quality made using an air bearing rotating coil system. The magnetic CL stability during -20% strength adjustment proposed for beam based alignment was < 0.2 microns. Strength hysteresis was negligible. Thermal expansion of quadrupole and measurement parts caused a repeatable and easily compensated change in the vertical magnetic CL. Calibration procedures as well as CL measurements made over a wider tuning range of 100% to 20% in strength useful for a wide range of applications will be described. The impact of eddy currents in the steel poles on the magnetic field during strength adjustments will be reported.
Keywords :
Apertures; Coils; Magnetic field measurement; Magnetic hysteresis; Magnetic levitation; Permanent magnets; Rotation measurement; Stability; Testing; Thermal expansion;
Conference_Titel :
Particle Accelerator Conference, 2005. PAC 2005. Proceedings of the
Print_ISBN :
0-7803-8859-3
DOI :
10.1109/PAC.2005.1591012