DocumentCode
3207607
Title
Inverter Performance Certification: Results from the Sandia Test Protocol
Author
Whitaker, Chuck ; Newmiller, Jeff ; Bower, Ward
Author_Institution
BEW Eng., San Ramon, CA
Volume
2
fYear
2006
fDate
38838
Firstpage
2219
Lastpage
2222
Abstract
This paper discusses results of the work to develop a test protocol for evaluating PV inverter performance, results obtained by testing to the protocol as required by the California Energy Commission (CEC), and the use of those results to develop and evaluate inverter performance models. This paper presents preliminary results of the modeling effort, comparing the models derived from CEC data with field measurements from sample systems. In addition to predicting system performance, this model may prove equally useful in evaluating the quality of the data generated by performing the test protocol
Keywords
certification; invertors; photovoltaic power systems; power convertors; solar cell arrays; CEC; California Energy Commission; PV arrays; PV inverter performance certification; PV system performance; Sandia test protocol; Certification; Costs; Inverters; Laboratories; Power generation; Power system modeling; Protocols; Testing; US Department of Energy; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Photovoltaic Energy Conversion, Conference Record of the 2006 IEEE 4th World Conference on
Conference_Location
Waikoloa, HI
Print_ISBN
1-4244-0017-1
Electronic_ISBN
1-4244-0017-1
Type
conf
DOI
10.1109/WCPEC.2006.279950
Filename
4060116
Link To Document