• DocumentCode
    3208080
  • Title

    Analysis of Performance Parameters for UK Domestic PV Systems

  • Author

    Pearsall, N.M. ; Hynes, K.M. ; Martin, C. ; Munzinger, M.

  • Author_Institution
    Northumbria Photovoltaics Applications Centre, Northumbria Univ., Newcastle upon Tyne
  • Volume
    2
  • fYear
    2006
  • fDate
    38838
  • Firstpage
    2300
  • Lastpage
    2303
  • Abstract
    The monitoring of system performance in the UK photovoltaic domestic field trial has resulted in the largest data set to date for domestic PV systems under UK conditions. In this paper, the performance ratio and annual yield values are discussed for a sample of 285 domestic systems on 18 sites across the UK. The spread of values and the nature of the system losses observed are discussed, along with the implications for design and operation of systems in UK locations
  • Keywords
    building integrated photovoltaics; losses; power system measurement; UK domestic PV systems; UK photovoltaic domestic field trial; performance parameters analysis; system design; system losses; system operation; system performance monitoring; Condition monitoring; Electromagnetic compatibility; Fixtures; Lamps; Performance analysis; Performance loss; Photovoltaic cells; Renewable energy resources; System performance; Tiles;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Photovoltaic Energy Conversion, Conference Record of the 2006 IEEE 4th World Conference on
  • Conference_Location
    Waikoloa, HI
  • Print_ISBN
    1-4244-0017-1
  • Electronic_ISBN
    1-4244-0017-1
  • Type

    conf

  • DOI
    10.1109/WCPEC.2006.279632
  • Filename
    4060136