Abstract :
This paper discusses the implementation of abort gap beam intensity monitoring at the Tevatron collider at Fermilab. There are two somewhat independent monitors which measure the intensity of the synchrotron light emitted by particles in the abort gaps. One system uses a gated Photomultiplier Tube (PMT) to measure the light intensity, and the other system uses a single lens telescope, gated image intensifier, and Charge Injection Device (CID) camera to image the beam.
Keywords :
Charge measurement; Colliding beam devices; Current measurement; Lenses; Monitoring; Particle beam measurements; Particle measurements; Photomultipliers; Synchrotrons; Telescopes;