  • Abstract
    Studies of photo-emission and field emission behavior in an RF gun have been carried out. Unexpected phenomena were observed. In situ changes in the cathode’s quantum efficiency and dark current with time were seen during operation of the photo-injector. These changes were correlated with the magnetostatic field at the cathode. In addition, multipacting has been observed under certain conditions. Recent measurements indicate a correlation between multipacting and anomalous photo-and field emission behavior.
  • Keywords
    Cathodes; Current measurement; Dark current; Magnetic field measurement; Magnetostatics; Pulse measurements; Radio frequency; Solenoids; Superconducting magnets; Time measurement;