DocumentCode
321116
Title
Fascicle selective recording with a nerve cuff electrode
Author
Struijk, Johannes J. ; Haugland, Morten K. ; Thomsen, Morten
Author_Institution
Center for Sensory Motor Interaction, Aalborg Univ., Denmark
Volume
1
fYear
1996
fDate
31 Oct-3 Nov 1996
Firstpage
361
Abstract
A multipolar split cuff electrode is used for fascicle selective recording of the electroneurogram (ENG) of the sciatic nerve of the rabbit. Several electrode configurations were evaluated with regarding to selectivity: the peroneal and tibial nerves were stimulated alternately and the ENG was recorded at different sides of the sciatic nerve. The results for two electrode configurations are presented
Keywords
bioelectric potentials; biological techniques; electrodes; neurophysiology; electrode configuration; electroneurogram; fascicle selective recording; multipolar split cuff electrode; peroneal nerves; rabbit sciatic nerve; sciatic nerve; tibial nerves; Animals; Biomedical electrodes; Engineering in Medicine and Biology Society; Foot; Humans; Muscles; Rabbits; Shape; Tungsten;