• DocumentCode
    3211442
  • Title

    Automatic Control Method of NO Removal by a Combination of Ozone Injection and Exhaust Gas Recirculation

  • Author

    Yoshioka, Yoshio ; Kondo, Hiroaki ; Tabata, Yasuharu ; Hatakenaka, Hayato ; Nakada, Katsushi

  • Author_Institution
    Kanazawa Inst. of Technol., Nonoichi
  • fYear
    2008
  • fDate
    5-9 Oct. 2008
  • Firstpage
    1
  • Lastpage
    7
  • Abstract
    NOx from diesel exhaust gases can be removed efficiently by a combination of ozone injection and exhaust gas recirculation. In order to industrialize the system, it is necessary to develop NO control system, because NO concentration changes largely by engine output power. In this study, we constructed a NO control system without using NOx sensor. As for control method, we adopted two control methods; the one is an ozone control under predetermined rate of exhaust gas recirculation and the second one is an energy minimum control. The detail of automatic control methods are introduced in this paper. NO control experiments were carried out using 2.4 kVA diesel engine generator, and NO emissions were successfully controlled by the system.
  • Keywords
    diesel engines; diesel-electric generators; exhaust systems; nitrogen compounds; ozone; pollution control; NO; automatic control method; diesel engine generator; diesel exhaust gas; energy minimum control; exhaust gas recirculation; ozone injection; Automatic control; Automatic generation control; Control systems; Diesel engines; Electrical equipment industry; Gases; Industrial control; Power generation; Temperature control; Valves;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industry Applications Society Annual Meeting, 2008. IAS '08. IEEE
  • Conference_Location
    Edmonton, Alta.
  • ISSN
    0197-2618
  • Print_ISBN
    978-1-4244-2278-4
  • Electronic_ISBN
    0197-2618
  • Type

    conf

  • DOI
    10.1109/08IAS.2008.121
  • Filename