Abstract :
The use of an identified model for the design of a feedback controller for an actual plant introduces strictures on the quality of the model which are different from those pertaining in open loop identification. For example, a model Pˆ is admissible for the design of a controller for the actual plant P only if the pair (Pˆ, P) is simultaneously stabilizable. This paper addresses the question of the quality of a model to be used for control design, by analysing the interplay between the plant P, the designed closed loop system T and the set of admissible models {Pˆ}. For given P and T we characterize the set of admissible models {Pˆ}, where admissible means that a controller designed from Pˆ and T yields a stable closed loop. Necessary conditions on (P, T) are derived for this set to be nonempty
Keywords :
closed loop systems; continuous time systems; control system synthesis; feedback; modelling; stability; transfer functions; closed loop system; continuous time systems; control design; feedback controller; model; necessary conditions; stabilization; transfer function; Adaptive systems; Closed loop systems; Control design; Control system analysis; Force control; Frequency; Open loop systems; Robustness; Systems engineering and theory; Transfer functions;