Title :
NEG Pumping Strip Inside Tevatron B2 Magnets
Author :
Chen, Alex ; Hanna, Bruce ; Anderson, Terry
Author_Institution :
FNAL Batavia, IL60510, USA
Abstract :
Nonevaporable getter (NEG) pumping strips[1][2][3], 6.2-m long, were installed inside four Tevatron B2 magnets to improve the vacuum environment. This established A linear pumping scheme in the long, unbakable vacuum chamber. The total pressure was reduced significantly.
Keywords :
Aluminum; Apertures; Assembly; Cooling; Gettering; Magnets; Space heating; Strips; Testing; Thermal expansion;
Conference_Titel :
Particle Accelerator Conference, 2005. PAC 2005. Proceedings of the
Print_ISBN :
0-7803-8859-3
DOI :
10.1109/PAC.2005.1591392