DocumentCode
3214180
Title
Fault Detection and Protection of Three-Level Neutral-Point-Clamped PWM Voltage Source Converters
Author
Wang, Fred ; Lai, Rixin ; Yuan, Xibo ; Luo, Fang ; Burgos, Rolando ; Boroyevich, Dushan
Author_Institution
Center for Power Electron. Syst., Virginia Polytech. Inst. & State Univ., Blacksburg, VA
fYear
2008
fDate
5-9 Oct. 2008
Firstpage
1
Lastpage
7
Abstract
This paper presents the detection and protection methods uniquely associated with three-level NPC voltage source converters. The line-to-ground fault can cause significant DC-link neutral voltage and therefore can be effectively detected and located through monitoring the voltage without extra hardware. The inner device short in the three-level phase-leg can lead to DC- link voltage unbalance and doubling the stress on capacitors and devices, which must be suppressed for the safe operation of the converter. Two overvoltage limiting methods are proposed to limit the overvoltage. The design of both the ground fault detection and overvoltage limiting has been covered in the paper. The schemes are verified through simulation and experiments.
Keywords
PWM power convertors; fault location; overvoltage protection; fault detection; fault location; line-to-ground fault; overvoltage limiting methods; protection methods; three-level neutral-point-clamped PWM voltage source converters; Circuit faults; Electrical fault detection; Fault detection; Impedance; Phase modulation; Power conversion; Protection; Pulse width modulation; Pulse width modulation converters; Voltage control;
fLanguage
English
Publisher
ieee
Conference_Titel
Industry Applications Society Annual Meeting, 2008. IAS '08. IEEE
Conference_Location
Edmonton, Alta.
ISSN
0197-2618
Print_ISBN
978-1-4244-2278-4
Electronic_ISBN
0197-2618
Type
conf
DOI
10.1109/08IAS.2008.281
Filename
4659069