DocumentCode
3214260
Title
Compensation of Switch Faults in a Three-Level Inverter
Author
Da Silva, Edison R C ; De O, Antônio S., Jr. ; Jacobina, Cursino B. ; Ribeiro, Ricardo L. ; Melo, Liviane C A ; Razik, Hubert
Author_Institution
DEE/CEEI, Univ. Fed. de Campina Grande, Campina Grande
fYear
2008
fDate
5-9 Oct. 2008
Firstpage
1
Lastpage
6
Abstract
This paper deals with open switch faults in a three-level inverter feeding a three-phase induction motor. It also investigates the fault compensation via topologies that are able to maintain the system operation for a period of time. With the proposed techniques it is possible to detect and identify the power switch in which the fault has occurred. Such detection requires the measurement of some voltages Differently from other schemes the proposed one allows, in some cases, full utilization of the dc-link. Simulated and experimental results verify the feasibility of proposed strategies. The results obtained so far indicate that it is possible to embed some fault-tolerant properties for the voltage-fed asynchronous machine drive system.
Keywords
fault diagnosis; induction motor drives; invertors; network topology; fault compensation; fault-tolerant properties; power switch; switch faults; three-level inverter; three-phase induction motor; voltage-fed asynchronous machine drive system; Capacitors; Circuit faults; Fault detection; Fault tolerance; Inverters; Jacobian matrices; Leg; Switches; Topology; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Industry Applications Society Annual Meeting, 2008. IAS '08. IEEE
Conference_Location
Edmonton, Alta.
ISSN
0197-2618
Print_ISBN
978-1-4244-2278-4
Electronic_ISBN
0197-2618
Type
conf
DOI
10.1109/08IAS.2008.285
Filename
4659073
Link To Document