Abstract
A wobbler magnet and an AC power supply for the MC-50 cyclotron (k=50) at Korea Institute of Radiological and Medical Sciences (KIRAMS) were designed and constructed to increase the area of beam irradiation. The power supply has two independently operating channels for the vertical and horizontal coils of the wobbler magnet. The frequency of the AC power supply for both coils is programmable from 1 to 20 Hz in a step of 1 Hz, and the maximum output current is 12 A rms. With the wobbler magnet, the uniform irradiation area of the proton beam increased ∼ 4 times larger than the one without the magnet, and various properties of the magnet and power supply system indicate that the system is well suited for many ion beam experiments.