DocumentCode :
3215994
Title :
Dynamic Aperture Study and Lifetime Improvement at the Advanced Photon Source
Author :
Sajaev, V. ; Emery, L.
Author_Institution :
ANL, Argonne, IL 60439, U.S.A., sajaev@aps.anl.gov
fYear :
2005
fDate :
16-20 May 2005
Firstpage :
3632
Lastpage :
3634
Abstract :
Over the past few years, the optics of the Advanced Photon Source storage ring has been optimized to provide lower natural emittance. Presently, the APS operates at 2.5 nm-rad emittance. The optimization was done at the expense of stronger sextupoles and shorter lifetime. Here we present our work on measurement and understanding of the dynamic aperture of the APS in low-emittance mode. We found good agreement between the dynamic aperture measurements and that of the model derived from the response matrix analysis. Based on the model, we were able to increase the lifetime significantly by optimizing sextupoles, correcting optics, moving a working point, and adjusting rf voltage. The higher lifetime allowed us to decrease operating coupling from 2.5% to 1%.
Keywords :
Apertures; Laboratories; Light sources; Loss measurement; Particle beam measurements; Particle tracking; Stability; Stimulated emission; Storage rings; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Particle Accelerator Conference, 2005. PAC 2005. Proceedings of the
Print_ISBN :
0-7803-8859-3
Type :
conf
DOI :
10.1109/PAC.2005.1591563
Filename :
1591563
Link To Document :
بازگشت