    1μs-conform line length of the Transparent Clock Mechanism defined by the Precision Time Protocol (PTP Version 2)

  • Author

    Scheiterer, Ruxandra Lupas ; Na, Chongning ; Obradovic, Dragan ; Steindl, Günter ; Goetz, Franz-Josef

  • Author_Institution
    Corp. Technol., Inf. & Commun., Siemens AG, Munich
  • fYear
    2008
  • fDate
    22-26 Sept. 2008
  • Firstpage
    92
  • Lastpage
    97
  • Abstract
    This paper quantifies the ldquo1 mus-conformrdquo line-length of the Transparent Clock Mechanism of peer-to-peer Precision Time Protocol (PTP Version 2), i.e. the number of elements that stay within the plusmn1 mus sync error tolerance, for crystal oscillator output frequencies of 100 MHz, 250 MHz, 500 MHz and 1 GHz, i.e. for time quantization errors of 10 ns, 4 ns, 2 ns and 1 ns.
  • Keywords
    IEEE standards; clocks; local area networks; protocols; crystal oscillator; line length; peer-to-peer precision time protocol; sync error tolerance; time quantization errors; transparent clock mechanism; Automation; Clocks; Electrical equipment industry; Error correction; Frequency synchronization; Jitter; Master-slave; Oscillators; Protocols; Stability; “1μs-conform” line-length; long-term stability; precision time protocol (PTP); shocks; short-term stability; synchronization precision; temperature drift; transparent clock; vibration;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Clock Synchronization for Measurement, Control and Communication, 2008. ISPCS 2008. IEEE International Symposium on
  • Conference_Location
    Ann Arbor, MI
  • Print_ISBN
    978-1-4244-2274-6
  • Electronic_ISBN
    978-1-4244-2275-3
  • Type

    conf

  • DOI
    10.1109/ISPCS.2008.4659220
  • Filename
    4659220