Abstract
This paper presents a series of randomly chosen examples from the author´s 25 years of involvement in circuit design for precision AC measurement. A general view of the extraordinary difficulties in attempting to achieve levels of measurement accuracy in AC comparable with those commonly achieved in DC is presented. The examples discussed all gave problems but in most cases finally were cured, often with valuable insight gained
Keywords
voltage measurement; circuit design; correction factor; dielectric constant; measurement accuracy; precision AC measurement; quadrature errors; self heating errors; series parallel equivalence; shifting errors; unconnected resistor; voltage measurement;