Abstract :
Working fluid filling is one of the most difficult problems normally encountered in micro/miniature heat pipe manufacturing and processing. Three methods for proper heat pipe filling are introduced and evaluated in this paper. These methods are referred to as the screw-piston valve/vacuum bypass, screw-piston valve/sealed reservoir, and micro-syringe/T-junction methods, respectively. The screw-piston/vacuum bypass method proves to be feasible but less accurate. The screw-piston/sealed reservoir fails to yield any meaningful result at the present time. However, the method based on the micro-syringe/T-junction proves to be quite successful, which yields a high filling accuracy and high vacuum condition in the heat pipe
Keywords :
heat pipes; testing; valves; filling station; high vacuum condition; micro heat pipe manufacturing; micro heat pipe processing; micro-syringe/T-junction method; miniature heat pipe manufacturing; miniature heat pipe processing; screw-piston valve/sealed reservoir method; screw-piston valve/vacuum bypass method; working fluid filling; Fabrication; Filling; Heat transfer; Needles; Reservoirs; Space charge; Space heating; Testing; Vacuum systems; Valves;