Title :
Review of features of fog chamber at the Ohio State University for polymer insulator evaluation
Author :
Sebo, Stephen A. ; Casale, Edgar P. ; Cedeno, J.R. ; Tjokrodiponto, Wibawa ; Akbar, Sheikh A. ; Sakich, John ; Zhao, Tiebin
Author_Institution :
Ohio State Univ., Columbus, OH, USA
Abstract :
Non-ceramic (composite) insulators consist of a fiberglass core rod surrounded by a polymer weather-shed housing. The housing is generally manufactured from an elastomer material. Weathershed materials may be subject to degradation and aging in service due to harsh environmental conditions. Performance evaluation of polymer weathersheds can employ fog chambers. Design and operational features of a new fog chamber are reviewed in this paper. Specific characteristics reviewed are: size and main layout of the chamber, insulator arrangement, high voltage source; protection, water circulation and data acquisition systems. Test cycles and techniques are also discussed briefly
Keywords :
ageing; elastomers; environmental degradation; fog; insulation testing; polymer insulators; Ohio State University; aging; degradation; elastomer material; fiberglass core rod; fog chamber; harsh environment; nonceramic composite insulator; polymer insulator testing; weather-shed housing; Aging; Data acquisition; Degradation; Manufacturing; Plastic insulation; Polymers; Protection; Testing; Voltage; Water resources;
Conference_Titel :
Electrical Insulation and Dielectric Phenomena, 1996., IEEE 1996 Annual Report of the Conference on
Conference_Location :
Millbrae, CA
Print_ISBN :
0-7803-3580-5
DOI :
10.1109/CEIDP.1996.564505