  • Abstract
    The paper presents an Angular Spectrum Approach (ASA) for simulating pulsed non-linear ultrasound fields. The source of the ASA is generated by Field II, which can simulate array transducers of any arbitrary geometry and focusing. The non-linear ultrasound simulation program - Abersim, is used as the reference. A linear array transducer with 64 active elements is simulated by both Field II and Abersim. The excitation is a 2-cycle sine wave with a frequency of 5 MHz. The second harmonic field in the time domain is simulated using ASA. Pulse inversion is used in the Abersim simulation to remove the fundamental and keep the second harmonic field, since Abersim simulates non-linear fields with all harmonic components. ASA and Abersim are compared for the pulsed fundamental and second harmonic fields in the time domain at depths of 30 mm, 40 mm (focal depth) and 60 mm. Full widths at -6 dB (FWHM) are {0.97, 0.95} mm at the focal depth for the fundamental fields for ASA and Abersim, and {0.56, 0.55} mm for the second harmonic fields. Full widths at -12 dB are {1.27, 1.26} mm for the fundamental fields for ASA and Abersim, and {0.77, 0.73} mm for the second harmonic fields. The calculation time, for the second harmonic fields, using ASA is 12 minutes and for all harmonic fields using Abersim is 14 hours. Compared to Abersim, the error of ASA for calculating the second harmonic fields is 1.5% at -6 dB and 6.4% at -12 dB, and the calculation time is reduced by a factor of 70.
  • Keywords
    acoustic field; harmonics; time-domain analysis; ultrasonic focusing; ultrasonics; ASA; Abersim simulation; angular spectrum approach; focusing; frequency 5 MHz; linear array transducer; pulse inversion; pulsed nonlinear ultrasound fields; second harmonic field; time domain; Acoustics; Arrays; Harmonic analysis; Imaging; Mathematical model; Transducers; Ultrasonic imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium (IUS), 2011 IEEE International
  • Conference_Location
    Orlando, FL
  • ISSN
    1948-5719
  • Print_ISBN
    978-1-4577-1253-1
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2011.0393
  • Filename
    6293278