Title :
Vibration-induced fatigue failures in bonding wires used in stacked chip modules
Author :
Leidecker, Henning ; Hull, Scott
Author_Institution :
Goddard Space Flight Center, Greenbelt, MD, USA
Abstract :
An instrument recently constructed at Goddard Space Flight Center involved stacked chip memory modules with about six thousand 1 mil gold wires, each between 4.6 mm and 6.1 mm long. Four bond wires fractured during the final box-level random vibration test, which had spectral power to 850 Hz. We determined that these wires have fundamental resonant frequencies in the range from 1.4 kHz to 2.3 kHz, with quality factors up to 300, when the bonds at each end are rigid. However, a nearly severed top bond decreases the lead´s fundamental frequency into the range from 600 Hz to 750 Hz. The lowered mode is strongly excited by the box-level vibration test, leading to fatigue-fracture of that already weakened bond during the several minutes of the vibration test. However, such a lowered mode would not be excited by previous shock and vibration tests, since these happened to have no spectral power in the region from 600 Hz to 750 Hz. In separate tests, an unfractured 1 mil gold wire was still intact after 12 days (1.4 billion oscillations) at 1.4 kHz at a root-strain of 0.2%, while several (deliberately) nearly fractured wires failed after less than a minute (less than 41,000 oscillations) at 680 Hz at the same drive stress
Keywords :
DRAM chips; Q-factor; dynamic testing; failure analysis; fatigue; gold; integrated circuit interconnections; integrated circuit packaging; integrated circuit reliability; lead bonding; multichip modules; space vehicle electronics; 1 mil; 1.4 to 2.3 kHz; 12 day; 4.6 to 6.1 mm; 600 to 750 Hz; 680 Hz; 850 Hz; Au; bond wire fracture; bonding wires; box-level random vibration test; box-level vibration test; drive stress; fatigue-fracture; gold wires; near-severed top bond; quality factors; rigid bond ends; shock tests; stacked DRAM chips; stacked chip memory modules; stacked chip modules; vibration test spectral power; vibration tests; vibration-induced fatigue failures; weakened bond; wire fundamental resonant frequencies; Bonding; Electric shock; Fatigue; Gold; Instruments; Q factor; Resonant frequency; Stress; Testing; Wires;
Conference_Titel :
Multichip Modules and High Density Packaging, 1998. Proceedings. 1998 International Conference on
Conference_Location :
Denver, CO
Print_ISBN :
0-7803-4850-8
DOI :
10.1109/ICMCM.1998.670799