DocumentCode :
3228947
Title :
PSD modifications of FHRV due to CTG storage rate
Author :
Cesarelli, M. ; Romano, M. ; Ruffo, M. ; Bifulco, P. ; Pasquariello, G. ; Fratini, A.
Author_Institution :
Dept. of Biomed., Electron. & Telecommun. Eng., Univ. Federico II, Naples, Italy
fYear :
2009
fDate :
4-7 Nov. 2009
Firstpage :
1
Lastpage :
4
Abstract :
Cardiotocographic data provide physicians information about foetal development and, through assessment of specific parameters (like accelerations, uterine contractions, ...), permit to assess conditions such as foetal distress. An incorrect evaluation of foetal status can be of course very dangerous. In the last decades, to improve interpretation of cardiotocographic recordings, great interest has been dedicated to FHRV spectral analysis. It is worth reminding that FHR is intrinsically an uneven series and that to obtain evenly sampled series, many commercial cardiotocographs use a zero-order interpolation (storage rate of CTG data equal to 4 Hz). This is not suitable for frequency analyses because interpolation introduces alterations in the FHR power spectrum. In particular, this interpolation process can produce artifacts and an attenuation of the high-frequency components of the PSD that, for example, affects the estimation of the sympatho-vagal balance (SVB computed as low-frequency/high-frequency ratio), which represents an important clinical parameter. In order to estimate the frequency spectrum alterations due to zero-order interpolation and other CTG storage rates, in this work, we simulated uneven FHR series with set characteristics, their evenly spaced versions (with different storage rates) and computed SVB values by PSD. For PSD estimation, we chose the Lomb method, as suggested by other authors in application to uneven HR series.
Keywords :
cardiology; interpolation; medical image processing; obstetrics; patient monitoring; spectral analysis; CTG storage rate; FHRV spectral analysis; Lomb method; PSD modifications; cardiotocographic data; cardiotocographic recordings; foetal development; foetal distress; frequency analyses; sympatho-vagal balance; zero-order interpolation; Acceleration; Attenuation; Biomedical engineering; Cardiography; Fetal heart rate; Frequency estimation; Heart beat; Heart rate; Interpolation; Spectral analysis; FHRV; Home Cardiotocography; Lomb method; Sympathovagal balance;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Information Technology and Applications in Biomedicine, 2009. ITAB 2009. 9th International Conference on
Conference_Location :
Larnaca
Print_ISBN :
978-1-4244-5379-5
Electronic_ISBN :
978-1-4244-5379-5
Type :
conf
DOI :
10.1109/ITAB.2009.5394444
Filename :
5394444
Link To Document :
بازگشت