Title : 
Continuous wave (CW) sub-Terahertz (sub-THz) detection by Plasma Wave in High Electron Mobility Transistor (HEMT)
         
        
            Author : 
Othman, Mohd Azlishah ; Harrison, Ian
         
        
            Author_Institution : 
Div. of Electr. Syst. & Opt., Univ. of Nottingham, Nottingham, UK
         
        
        
        
        
        
            Abstract : 
We report on the detection of CW sub-THz (300 GHz) radiation by High Electron Mobility Transistor (HEMT). The observed photo-response are measured against gate voltage. The measured response is a superposition of a generally increasing response with a decrease in VGS coupled with a small peak approximately at threshold. The response has also been measured as a function of frequency and there is evidence that the response against VGS characteristic does depend on frequency.
         
        
            Keywords : 
high electron mobility transistors; plasma waves; terahertz wave detectors; continuous wave sub-terahertz detection; high electron mobility transistor; photoresponse; plasma wave; Current measurement; Detectors; Frequency measurement; HEMTs; Logic gates; Voltage measurement; Detection; HEMTs; Sub-Terahertz;
         
        
        
        
            Conference_Titel : 
Circuits and Systems (APCCAS), 2010 IEEE Asia Pacific Conference on
         
        
            Conference_Location : 
Kuala Lumpur
         
        
            Print_ISBN : 
978-1-4244-7454-7
         
        
        
            DOI : 
10.1109/APCCAS.2010.5774906