• DocumentCode
    3229769
  • Title

    Development of low cost radiated emission measurement system

  • Author

    Huang, Zihong ; Chen, Wenhua ; Feng, Zhenghe ; Toyama, K. ; Teshima, K.

  • Author_Institution
    Dept. of Electron. Eng., Tsinghua Univ., Beijing, China
  • fYear
    2010
  • fDate
    8-11 May 2010
  • Firstpage
    1829
  • Lastpage
    1832
  • Abstract
    A novel low cost radiated emission measurement system by using current probe has been proposed in this paper. Compared with conventional anechoic chamber measurement method, this new method could reduce test cost and save developing time efficiently. In order to improve the accuracy, a transfer function has been built for mapping the relationship between current probe method and anechoic chamber method. By using the interpolation, the final estimated radiation emission has been validated and agreed well with the experimental results in anechoic chamber.
  • Keywords
    Taguchi methods; anechoic chambers (electromagnetic); electromagnetic compatibility; interpolation; anechoic chamber measurement method; current probe method; interpolation; radiated emission measurement system; transfer function; Costs; Current measurement; Electromagnetic compatibility; Frequency measurement; IEC standards; Noise measurement; Probes; Signal detection; Testing; Transfer functions; Taguchi method; radiated emission; transfer function;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microwave and Millimeter Wave Technology (ICMMT), 2010 International Conference on
  • Conference_Location
    Chengdu
  • Print_ISBN
    978-1-4244-5705-2
  • Type

    conf

  • DOI
    10.1109/ICMMT.2010.5524864
  • Filename
    5524864