DocumentCode
3229769
Title
Development of low cost radiated emission measurement system
Author
Huang, Zihong ; Chen, Wenhua ; Feng, Zhenghe ; Toyama, K. ; Teshima, K.
Author_Institution
Dept. of Electron. Eng., Tsinghua Univ., Beijing, China
fYear
2010
fDate
8-11 May 2010
Firstpage
1829
Lastpage
1832
Abstract
A novel low cost radiated emission measurement system by using current probe has been proposed in this paper. Compared with conventional anechoic chamber measurement method, this new method could reduce test cost and save developing time efficiently. In order to improve the accuracy, a transfer function has been built for mapping the relationship between current probe method and anechoic chamber method. By using the interpolation, the final estimated radiation emission has been validated and agreed well with the experimental results in anechoic chamber.
Keywords
Taguchi methods; anechoic chambers (electromagnetic); electromagnetic compatibility; interpolation; anechoic chamber measurement method; current probe method; interpolation; radiated emission measurement system; transfer function; Costs; Current measurement; Electromagnetic compatibility; Frequency measurement; IEC standards; Noise measurement; Probes; Signal detection; Testing; Transfer functions; Taguchi method; radiated emission; transfer function;