Abstract :
Previous efforts by our group have demonstrated the potential of hybrid semiconductor detector arrays for use in gamma-ray imaging applications. In this paper, we describe progress in the development of a prototype imaging system consisting of a 64×64-pixel CdZnTe detector array mated to a multiplexer readout circuit that was custom designed for our nuclear medicine application. The detector array consists of a 0.15 cm thick slab of CdZnTe which has a 64×64 array of 380 μm square pixel electrodes on one side produced by photolithography; the other side has a continuous electrode biased at -150 V. Electrical connections between the detector electrodes and corresponding multiplexer bump pads are made with indium bump bonds. Although the CdZnTe detector arrays characterized in this paper are room-temperature devices, a slight amount of cooling is necessary to reduce thermally generated dark current in the detectors. Initial tests show that this prototype imager functions well with more than 90% of its pixels operating. The device is an excellent imager; phantom images have a spatial resolution of 1.5 mm, limited by the collimator bore
Keywords :
II-VI semiconductors; brain; cadmium compounds; gamma-ray detection; semiconductor counters; single photon emission computed tomography; zinc compounds; -150 V; CdZnTe; SPECT; brain imaging; collimator bore; continuous electrode; gamma-ray imaging; hybrid semiconductor detector arrays; large-area modular imaging arrays; multiplexer bump pads; multiplexer readout circuit; nuclear medicine; phantom images; prototype imaging system; single-photon emission computed tomography; square pixel electrodes; thermally generated dark current; Biomedical electrodes; Circuits; Gamma ray detection; Gamma ray detectors; Multiplexing; Nuclear imaging; Nuclear medicine; Optical imaging; Prototypes; Sensor arrays;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium, 1997. IEEE
Conference_Location :
Albuquerque, NM
ISSN :
1082-3654
Print_ISBN :
0-7803-4258-5
Type :
conf
DOI :
10.1109/NSSMIC.1997.672584
Filename :
672584
Link To Document :
بازگشت