DocumentCode :
3232918
Title :
A clinical experience of a prototype automated breast ultrasound system combining transmission and reflection 3D imaging
Author :
Pellegretti, P. ; Vicari, M. ; Zani, M. ; Weigel, M. ; Borup, D. ; Wiskin, J. ; Saueressig, U. ; Kotter, E. ; Langer, M.
Author_Institution :
Esaote S.p.a., Genoa, Italy
fYear :
2011
fDate :
18-21 Oct. 2011
Firstpage :
1407
Lastpage :
1410
Abstract :
A new ultrasound CT breast WBU (Warm Bath Ultrasound) Scanner developed by Techniscan Medical Systems, Salt Lake City, Utah, USA, and supported by Esaote Spa, Genoa, Italy, was installed for pre-clinical testing at the Department of Radiology, Clinical Radiology, University Medical Center Freiburg, Freiburg, Germany. The system acquires a volume dataset of both transmission and reflection of the whole breast. A 3D inverse scattering algorithm generates 3D maps of both speed of sound and attenuation of tissues, along with a 3D reflection map geometrically registered with the previous ones. The pilot study examination protocol included breast WBU, handheld ultrasound and mammography for every patient. MRI was used when recommended for diagnostic purposes. In cases of suspected malignancy, vacuum core biopsy was conducted. A total of 60 patients were included in the study. As result, 10 out of 12 carcinomas were detected in the WBU examinations. In 2 cases, carcinoma close to the chest wall laid outside the field of view. Fibroadenomas and cysts were depicted reliably. Lesion characteristics differ markedly from handheld ultrasound. Speed of sound and attenuation images may increase the lesions characterization reliability.
Keywords :
biological organs; biological tissues; biomedical MRI; biomedical ultrasonics; cancer; cellular biophysics; computerised tomography; gynaecology; mammography; medical image processing; 3D inverse scattering algorithm; 3D maps; 3D reflection map; MRI; attenuation imaging; carcinomas; chest wall; clinical radiology; cysts; fibroadenomas; handheld ultrasound mammography; lesion characterization reliability; malignancy; pilot study examination protocol; preclinical testing; prototype automated breast ultrasound system; reflection 3D imaging; sound speed; tissues; transmission 3D imaging; ultrasound CT breast WBU scanner; vacuum core biopsy; whole breast; Attenuation; Breast; Magnetic resonance imaging; Radiology; Reflection; Ultrasonic imaging;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Ultrasonics Symposium (IUS), 2011 IEEE International
Conference_Location :
Orlando, FL
ISSN :
1948-5719
Print_ISBN :
978-1-4577-1253-1
Type :
conf
DOI :
10.1109/ULTSYM.2011.0348
Filename :
6293563