DocumentCode :
3234461
Title :
Analysis and research of the buried U-PVC pipe of the water supply function
Author :
Zhou, Jing-hai ; Zhang, Xiao-lei
Author_Institution :
Sch. of Civil Eng., Shenyang Jianzhu Univ., Shenyang, China
fYear :
2011
fDate :
22-24 April 2011
Firstpage :
3866
Lastpage :
3870
Abstract :
The anti-seismic characters of earthing U-PVC supply pipeline is analysed by the pull-off test of flexible joint static-load on the earthing U-PVC supply pipeline. Under the condition of earthing, the test of tensile static-load is going through five pipes 200mm dia., which is connected with cushion rubber, meanwhile, five displacement conditions have been done on each pipe. According to the test data of the pressure and the displacement, a relative curve about pressure-displacement has been accepted and its formula has been formed. Under the relationship between leakage-amount and the time on each condition, a leakage model is built. The analysis suggests that such a tube of flow can be used as an available model only when the supply pipe net with leakage is analysed. The formula about hydraulic pressure to displacement at the interface provides the reference information for the anti-seismic design of the supply pipeline.
Keywords :
pipelines; tensile strength; vibrations; water supply; U-PVC supply pipeline; antiseismic characters; buried U-PVC pipe; cushion rubber; earthing; leakage model; pressure-displacement; tensile static-load; water supply function; Civil engineering; Educational institutions; Electron tubes; Grounding; Pipelines; Reliability engineering; Vibrations; U-PVC pipe; corresponding displacement - water pressure curvesand; flexible interface; seepage models;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electric Technology and Civil Engineering (ICETCE), 2011 International Conference on
Conference_Location :
Lushan
Print_ISBN :
978-1-4577-0289-1
Type :
conf
DOI :
10.1109/ICETCE.2011.5775146
Filename :
5775146
Link To Document :
بازگشت