• DocumentCode
    3234737
  • Title

    Calibrated measurements of nonlinearities in narrowband amplifiers applied to intermodulation and cross modulation compensation

  • Author

    van den Broeck, T.

  • Author_Institution
    Vrije Univ., Brussels, Belgium
  • fYear
    1995
  • fDate
    16-20 May 1995
  • Firstpage
    1155
  • Abstract
    A vectorial nonlinear-network analyzer (VNNA) is absolutely calibrated in amplitude and phase for narrowband measurements of nonlinearities. Calibration is performed with a reference generator, characterized with a calibrated sampling oscilloscope. The reference signal, consisting of an upconverted baseband signal, is optimized for statistically efficient measurements. Using the calibrated VNNA, narrowband amplifiers can be measured, enabling compensation of intermodulation and cross-modulation.<>
  • Keywords
    amplifiers; calibration; circuit testing; compensation; intermodulation; network analysers; calibrated VNA; calibrated measurements; calibrated sampling oscilloscope; cross modulation compensation; intermodulation compensation; narrowband amplifiers; nonlinearities; reference generator; statistically efficient measurements; upconverted baseband reference signal; vectorial nonlinear network analyzer; Calibration; Character generation; Chromium; Distortion measurement; Narrowband; Oscilloscopes; Phase measurement; Sampling methods; Signal generators; System testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microwave Symposium Digest, 1995., IEEE MTT-S International
  • Conference_Location
    Orlando, FL, USA
  • ISSN
    0149-645X
  • Print_ISBN
    0-7803-2581-8
  • Type

    conf

  • DOI
    10.1109/MWSYM.1995.406171
  • Filename
    406171