Title :
The significance of partial discharge measurements for verification of insulation integrity in a low pressure environment
Author :
Grosjean, D. ; Schweickart, D. ; Kasten, D. ; Liu, X. ; Sebo, S.
Author_Institution :
Innovative Sci. Solutions Inc., Dayton, OH
Abstract :
Partial discharge (PD) characteristics in air and argon under low pressure (0.1-760 Torr) and 60 Hz AC energization are described for an energized needle -grounded plane electrode arrangement. The paper focuses on PD tests conducted, and the significance of the test results on the requirements related to commercially available PD detection equipment
Keywords :
air; aircraft power systems; argon; earth electrodes; insulation testing; partial discharge measurement; power system reliability; 0.1 Torr to 760 Torr; 60 Hz; PD detection equipment; PD tests; aerospace vehicles; air; argon; energized needle -grounded plane electrode; insulation integrity; insulation reliability; low pressure environment; partial discharge measurements; Aerospace testing; Argon; Dielectrics and electrical insulation; Electrodes; Gas insulation; Partial discharge measurement; Partial discharges; Pressure measurement; System testing; Voltage;
Conference_Titel :
Power Modulator Symposium, 2004 and 2004 High-Voltage Workshop. Conference Record of the Twenty-Sixth International
Conference_Location :
San Francisco, CA
Print_ISBN :
0-7803-8586-1
DOI :
10.1109/MODSYM.2004.1433500