DocumentCode :
3236696
Title :
Bias and linearity measurement of three axis fluxgate magnetometers using high precise electromagnetic devices
Author :
Pang, Hong Feng ; Luo, Shi Tu ; Pan, Meng Chun ; Chen, Di Xiang ; Luo, Fei Lu ; Zhang, Qi
Author_Institution :
Coll. of Mechatron. Eng. & Autom., Nat. Univ. of Defense Technol., Changsha, China
fYear :
2011
fDate :
14-16 Dec. 2011
Firstpage :
17
Lastpage :
21
Abstract :
Bias error and linearity error influence the measurement precision of three axis fluxgate magnetometers. So, it is important to obtain and calibrate these errors. Bias error and linearity error of a German made DM-060 digital magnetometer are measured by precise electromagnetic devices. Firstly, bias of each axis is obtained by an alternating weak electromagnetic standard equipment. A method by comparing mean absolute error before and after calibration is proposed to demonstrate the bias results credibility. Then, the rotating method is proposed to measure bias by a horizontal barrel shield equipment. Lastly, linearity error of each axis is obtained by a low DC electromagnetic field standard system, and linearity coefficients are calculated by linearity fitting. Experimental results show that bias of X, Y and Z axis is -2.9 nT, -1.4 nT and 3.9 nT by the alternating weak electromagnetic standard equipment, respectively. Bias of each axis changes to -5 nT, -2.5 nT and 10.5 nT by the horizontal barrel shield equipment a year later. Linearity error of X axis, Y axis and Z axis is 3.78-e005, 4.51-e005 and 7.92-e005, respectively. These experimental results show that there is a promising application to use high precise electromagnetic devices for measuring and calibrating bias error and linearity error.
Keywords :
electromagnetic devices; fluxgate magnetometers; magnetic field measurement; DC electromagnetic field standard system; DM-060 digital magnetometer; high precise electromagnetic devices; horizontal barrel shield equipment; linearity fitting; linearity measurement; mean absolute error; three axis fluxgate magnetometers; Coils; Current measurement; Linearity; Magnetic field measurement; Magnetic fields; Magnetometers; Measurement uncertainty; alternating weak electromagnetic standard equipment; bias error; horizontal barrel shield equipment; linearity error; low DC electromagnetic field standard system; three axis fluxgate magnetometer;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Applied Superconductivity and Electromagnetic Devices (ASEMD), 2011 International Conference on
Conference_Location :
Sydney, NSW
Print_ISBN :
978-1-4244-7852-1
Type :
conf
DOI :
10.1109/ASEMD.2011.6145057
Filename :
6145057
Link To Document :
بازگشت