DocumentCode
3239838
Title
Effect of unbalance in voltage supply on the detection of mixed air gap eccentricity in an induction motor by Motor Current Signature Analysis
Author
Samaga, R.L. ; Vittal, K.P. ; Vikas, J.
Author_Institution
Dept. of E&E, NITK - Surathkal, Surathkal, India
fYear
2011
fDate
1-3 Dec. 2011
Firstpage
108
Lastpage
113
Abstract
Condition monitoring units are employed in industries to monitor the health of the machines continuously. Air gap eccentricity fault is one of the asymmetrical faults which can result in the machine failure. Motor Current Signature Analysis and Vibration Analysis are the two most popular methods used for eccentricity fault detection in the induction motor. In this paper, a study conducted on an induction motor to analyse the effect of supply voltage unbalance on the method of eccentricity fault detection by Motor Current Signature Analysis is presented. A dynamic model of the induction motor suffering from air gap eccentricity and has the capability to take unbalance supply voltage is developed and the results obtained by simulating this model are validated by the experiments conducted on an induction motor suffering from inclined mixed eccentricity and fed with unbalance voltage supply.
Keywords
condition monitoring; fault diagnosis; induction motors; vibrations; asymmetrical faults; condition monitoring units; induction motor; machine failure; mixed-air gap eccentricity fault detection; motor current signature analysis; vibration analysis; voltage supply unbalance; Analytical models; Harmonic analysis; Induction motors; Mathematical model; Power harmonic filters; Stators; Voltage control; Motor Current Signature Analysis; air gap eccentricity; data acquisition system; induction motor;
fLanguage
English
Publisher
ieee
Conference_Titel
Innovative Smart Grid Technologies - India (ISGT India), 2011 IEEE PES
Conference_Location
Kollam, Kerala
Print_ISBN
978-1-4673-0316-3
Type
conf
DOI
10.1109/ISET-India.2011.6145365
Filename
6145365
Link To Document