• DocumentCode
    3243525
  • Title

    Development of a variable density flowmeter for an industrial application using tomographic imaging

  • Author

    Young, M. ; Pickup, E. ; Deloughry, R. ; Hartley, T. ; Nixon, S.A. ; Barratt, L.

  • Author_Institution
    Manchester Metropolitan Univ., UK
  • fYear
    1996
  • fDate
    35235
  • Abstract
    A variable density flowmeter enables the mass flow of plastic nibs to be measured. The flowmeter is situated between the bunker discharge outlet valve and tanker. Measurement of the density distribution across the pipe using process tomography enables the mass flow into the tankers to be determined. A high frequency (1 MHz), eight electrode serial capacitance sensing system was developed. This was used primarily for imaging static objects and real time imaging up to 2-3 frames per second. To increase the imaging speed a parallel system (PT II) was developed. The PT II system consists of an eight electrode parallel capacitance sensing system, using a low frequency AC amplifier detector circuit. The use of a low frequency source has made the capacitance detector circuit stray immune and less sensitive to high frequency noise. A PC based, Texas TMS C40 parallel processing system is used to process data and provide the tomographic images
  • Keywords
    flow measurement; PC based Texas TMS C40 parallel processing system; bunker discharge outlet valve; density distribution; eight electrode parallel capacitance sensing system; industrial application; low frequency AC amplifier detector circuit; mass flow; pipe; plastic nibs; process tomography; tanker; tomographic images; tomographic imaging; variable density flowmeter;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Advances in Electrical Tomography (Digest No: 1196/143), IEE Colloquium on
  • Conference_Location
    London
  • Type

    conf

  • DOI
    10.1049/ic:19960842
  • Filename
    577559