DocumentCode
3245762
Title
Corona defection for OF cable and oil reactor on running by loop antenna
Author
Higuchi, Takemitsu
Author_Institution
Res. Center, Kansai Electr. Power Co. Inc., Hyogo, Japan
fYear
1999
fDate
1999
Firstpage
537
Lastpage
540
Abstract
The author attempts to detect the corona pulse that occurs inside the power shunt-reactor and power cable at an early stage of insulation degeneration with an outside loop antenna. The principle of the method is described and the technique is applied to the case of corona pulse measurement caused by a partial discharge inside a shunt-reactor. Frequency spectra of the detected pulses are presented. A second example involves measurement of corona pulse from 77 kV OF cable
Keywords
corona; insulating oils; insulation testing; loop antennas; partial discharge measurement; power cable insulation; power cable testing; pulse measurement; saturable core reactors; 154 kV; 20 to 50 MHz; 77 kV; OF cable; corona pulse detection; frequency spectra; insulation degeneration; oil reactor; outside loop antenna; partial discharge; power cable; power shunt-reactor; Antenna measurements; Cable insulation; Corona; Frequency; Inductors; Oil filled cables; Partial discharges; Petroleum; Power cables; Pulse measurements;