DocumentCode
3247103
Title
An overview of Pekan Lightning Detection System (PLDS)
Author
Ibrahim, W.I. ; Ghazali, M.R.
Author_Institution
Fac. of Electr. & Electron. Eng., Univ. Malaysia Pahang, Pekan, Malaysia
fYear
2012
fDate
2-5 Dec. 2012
Firstpage
718
Lastpage
723
Abstract
Pekan is located at east of peninsular Malaysia which experience very high cloud to ground (CG) lightning density. The lightning strike hazards can be properly managed by using a lightning location system (LLS). In this paper, a system to monitor the lightning strikes and thunderstorm has been installed and setup. Pekan Lightning Detection System (PLDS) has a combination of Magnetics Direction Finder and Time-of - Arrival sensor. The PLDS provides both real-time and historical lightning data. The real-time data include the time of lightning strokes, their location and an estimate of the peak current.
Keywords
lightning protection; LLS; PLDS; Pekan lightning detection system; cloud-to-ground lightning density; historical lightning data; lightning location system; lightning strike hazards; magnetic direction finder; peak current estimation; peninsular Malaysia; real-time data; thunderstorm; time-of-arrival sensor; Conferences; Lightning; Magnetics; Radiation detectors; Real-time systems; Storms; Lighning Location System (LLS); Magnetics Direction Finding; PLDS; thunderstorm;
fLanguage
English
Publisher
ieee
Conference_Titel
Power and Energy (PECon), 2012 IEEE International Conference on
Conference_Location
Kota Kinabalu
Print_ISBN
978-1-4673-5017-4
Type
conf
DOI
10.1109/PECon.2012.6450308
Filename
6450308
Link To Document