• DocumentCode
    3247103
  • Title

    An overview of Pekan Lightning Detection System (PLDS)

  • Author

    Ibrahim, W.I. ; Ghazali, M.R.

  • Author_Institution
    Fac. of Electr. & Electron. Eng., Univ. Malaysia Pahang, Pekan, Malaysia
  • fYear
    2012
  • fDate
    2-5 Dec. 2012
  • Firstpage
    718
  • Lastpage
    723
  • Abstract
    Pekan is located at east of peninsular Malaysia which experience very high cloud to ground (CG) lightning density. The lightning strike hazards can be properly managed by using a lightning location system (LLS). In this paper, a system to monitor the lightning strikes and thunderstorm has been installed and setup. Pekan Lightning Detection System (PLDS) has a combination of Magnetics Direction Finder and Time-of - Arrival sensor. The PLDS provides both real-time and historical lightning data. The real-time data include the time of lightning strokes, their location and an estimate of the peak current.
  • Keywords
    lightning protection; LLS; PLDS; Pekan lightning detection system; cloud-to-ground lightning density; historical lightning data; lightning location system; lightning strike hazards; magnetic direction finder; peak current estimation; peninsular Malaysia; real-time data; thunderstorm; time-of-arrival sensor; Conferences; Lightning; Magnetics; Radiation detectors; Real-time systems; Storms; Lighning Location System (LLS); Magnetics Direction Finding; PLDS; thunderstorm;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power and Energy (PECon), 2012 IEEE International Conference on
  • Conference_Location
    Kota Kinabalu
  • Print_ISBN
    978-1-4673-5017-4
  • Type

    conf

  • DOI
    10.1109/PECon.2012.6450308
  • Filename
    6450308