DocumentCode
3249046
Title
Partial discharge patterns and aging phenomena at different temperatures in filled and unfilled epoxy, by a modified CIGRE setup, method I
Author
Schifani, R. ; Gagliardo, V.
Author_Institution
Dept. of Electr. Eng., Palermo Univ., Italy
fYear
1995
fDate
10-13 Jul 1995
Firstpage
329
Lastpage
333
Abstract
Some hypotheses about the effect of temperature on discharge mechanisms are put forward, thus giving a more complete view of partial discharge activity as far as material working conditions are concerned. Results show the possibility, by partial discharge amplitude distributions (PDAD) analysis performed within different test voltage phase windows and with different voltage levels, to model discharge mechanisms inside an enclosed cavity in different thermal conditions
Keywords
ageing; epoxy insulation; filled polymers; insulation testing; partial discharges; surface discharges; 20 to 80 C; 25 kV; 50 Hz; PDAD analysis; aging phenomena; discharge mechanisms; enclosed cavity; filled epoxy; modified CIGRE setup; partial discharge activity; partial discharge amplitude distributions; partial discharge patterns; temperature effects; test voltage phase windows; thermal conditions; unfilled epoxy; voltage levels; Aging; Electrodes; Employee welfare; Epoxy resins; Ignition; Partial discharges; Pulse measurements; Temperature; Testing; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Conduction and Breakdown in Solid Dielectrics, 1995. ICSD'95., Proceedings of the 1995 IEEE 5th International Conference on
Conference_Location
Leicester
Print_ISBN
0-7803-2040-9
Type
conf
DOI
10.1109/ICSD.1995.523003
Filename
523003
Link To Document