DocumentCode
3250114
Title
Calibration of Optical Probe for CMM
Author
Liu Shugui ; Tang Shaliang ; Chen Chao
Author_Institution
State Key Lab. of Precision Meas. Technol. & Instrum., Tianjin Univ., Tianjin, China
fYear
2009
fDate
14-16 Aug. 2009
Firstpage
1
Lastpage
4
Abstract
A posture error compensation method of optical probe, which is installed with a PH10 rotating head for the scanning measurement of coordinate measuring machine (CMM), is presented in this paper. The error compensation mathematical model is derived from the least square fitting method and an optimization algorithm is applied to determine the optimal parameters. Through the experiments, the arithmetic´s accuracy and the calibration effectiveness of optical probe are proved.
Keywords
calibration; coordinate measuring machines; error compensation; least squares approximations; optimisation; PH10 rotating head; calibration; coordinate measuring machine; least square fitting; optical probe; optimization; posture error compensation; scanning measurement; Arithmetic; Calibration; Coordinate measuring machines; Error compensation; Least squares methods; Magnetic heads; Mathematical model; Optimization methods; Probes; Rotation measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Photonics and Optoelectronics, 2009. SOPO 2009. Symposium on
Conference_Location
Wuhan
Print_ISBN
978-1-4244-4412-0
Type
conf
DOI
10.1109/SOPO.2009.5230075
Filename
5230075