DocumentCode
3251718
Title
High power amplifier harmonic output level measurement
Author
Perez, Rosa M. ; Hoppe, D.J. ; Khan, Ab Rouf
Author_Institution
Jet Propulsion Lab., California Inst. of Technol., Pasadena, CA, USA
fYear
1995
fDate
16-20 May 1995
Firstpage
1609
Abstract
A method is presented for the measurement of the harmonic output power of high power klystron amplifiers, involving coherent hemispherical radiation pattern measurements of the radiated klystron output. Results are discussed for operation in saturated and unsaturated conditions, and with a waveguide harmonic filter included.<>
Keywords
harmonics; klystrons; microwave power amplifiers; coherent hemispherical radiation pattern measurements; harmonic output level measurement; high power amplifier; klystron amplifiers; radiated klystron output; saturated conditions; unsaturated conditions; waveguide harmonic filter; Antenna radiation patterns; Frequency measurement; High power amplifiers; Klystrons; Level measurement; Power amplifiers; Power harmonic filters; Power measurement; Power system harmonics; Transmitters;