• DocumentCode
    3252581
  • Title

    Robustness evaluation of corner detectors for use in ultrasound image processing

  • Author

    Zukal, Martin ; Benes, Radek ; Cika, Petr ; Xintao Qiu

  • Author_Institution
    Brno Univ. of Technol., Brno, Czech Republic
  • fYear
    2013
  • fDate
    2-4 July 2013
  • Firstpage
    763
  • Lastpage
    767
  • Abstract
    This article deals with evaluation of suitability of interest point detectors (specifically corner detectors) for utilization in ultrasound image processing. Namely, the Harris detector, FAST (Features from Accelerated Segment Test) detector and Kanade-Lucas-Tomasi (KLT) detector have been tested on two data sets of ultrasound (US) images. The evaluation process consists of three experiments in which the images have been artificially corrupted by different types of noise or their brightness has been uniformly changed. The FAST detector proved to be more robust against noise than Harris and KLT detectors whereas the Harris and KLT detector outperformed FAST detector in case of brightness change.
  • Keywords
    biomedical ultrasonics; edge detection; medical image processing; ultrasonic imaging; FAST detector; Harris detector; Kanade-Lucas-Tomasi detector; corner detectors; features from accelerated segment test; interest point detectors; robustness evaluation; ultrasound image processing; Arteries; Brightness; Detectors; Noise; Robustness; Speckle; Ultrasonic imaging; FAST; Harris detector; KLT detector; Kanade-Lucas-Tomasi detector; corner detector; evaluation; speckle noise; ultrasound image;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Telecommunications and Signal Processing (TSP), 2013 36th International Conference on
  • Conference_Location
    Rome
  • Print_ISBN
    978-1-4799-0402-0
  • Type

    conf

  • DOI
    10.1109/TSP.2013.6614041
  • Filename
    6614041