Abstract
Surface tracking on carbon based solid insulators is one of the main reasons for failure in high voltage systems. Due to the various factors, such as humidity, flow rate, pollution, local voltage, etc., it is hard to make an estimation about the life of an insulator. Also, in contrast to the internal 3-dimensional treeing, 2-dimensional surface tracking has attracted little research effort. The model described simulates the tracking process, which consists of two stages, initiation and track growth
Keywords
Weibull distribution; carbon; failure analysis; humidity; insulator contamination; insulator testing; 2-dimensional surface tracking; C; carbon based solid insulators; failure; failure prediction; flow rate; high voltage systems; humidity; initiation; insulator life; internal 3-dimensional treeing; local voltage; pollution; surface tracking model; track growth; Carbon dioxide; Humidity; Insulation life; Life estimation; Pollution; Predictive models; Solids; Surface contamination; Trees - insulation; Voltage;