• DocumentCode
    3257564
  • Title

    Current source design of the reference laser diode for space-borne Fourier transform spectrometer

  • Author

    Xiaoqiang Jin ; Zuoxiao Dai ; Ren Chen ; Dayu Li ; Xiaojie Sun

  • Author_Institution
    Shanghai Inst. of Tech. Phys., Chinese Acad. of Sci., Shanghai, China
  • Volume
    6
  • fYear
    2010
  • fDate
    16-18 Oct. 2010
  • Firstpage
    2905
  • Lastpage
    2908
  • Abstract
    A laser diode is adopted as the reference light source in the Fourier transform spectrometer. Due to the high spectral accuracy, the fluctuation of the current source that drives the laser diode should be less than 15 uA. A high precision current source for the laser diode is described in this paper. The principle is analyzed and the simulation is realized. Experiments are setup and test data are obtained. It is found that the stability of the current source is better than 10 uA.
  • Keywords
    Fourier transform spectrometers; MOSFET; laser frequency stability; operational amplifiers; optical testing; remote sensing by laser beam; semiconductor lasers; current fluctuation; frequency stability; high precision current source design; laser diode; op-amp; optical testing; space-borne Fourier transform spectrometer; Circuit stability; Diode lasers; Fourier transforms; Laser stability; Semiconductor lasers; Stability analysis; Thermal stability; Fourier transform spectrometer; current source; laser diode;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Image and Signal Processing (CISP), 2010 3rd International Congress on
  • Conference_Location
    Yantai
  • Print_ISBN
    978-1-4244-6513-2
  • Type

    conf

  • DOI
    10.1109/CISP.2010.5646829
  • Filename
    5646829