DocumentCode
3257564
Title
Current source design of the reference laser diode for space-borne Fourier transform spectrometer
Author
Xiaoqiang Jin ; Zuoxiao Dai ; Ren Chen ; Dayu Li ; Xiaojie Sun
Author_Institution
Shanghai Inst. of Tech. Phys., Chinese Acad. of Sci., Shanghai, China
Volume
6
fYear
2010
fDate
16-18 Oct. 2010
Firstpage
2905
Lastpage
2908
Abstract
A laser diode is adopted as the reference light source in the Fourier transform spectrometer. Due to the high spectral accuracy, the fluctuation of the current source that drives the laser diode should be less than 15 uA. A high precision current source for the laser diode is described in this paper. The principle is analyzed and the simulation is realized. Experiments are setup and test data are obtained. It is found that the stability of the current source is better than 10 uA.
Keywords
Fourier transform spectrometers; MOSFET; laser frequency stability; operational amplifiers; optical testing; remote sensing by laser beam; semiconductor lasers; current fluctuation; frequency stability; high precision current source design; laser diode; op-amp; optical testing; space-borne Fourier transform spectrometer; Circuit stability; Diode lasers; Fourier transforms; Laser stability; Semiconductor lasers; Stability analysis; Thermal stability; Fourier transform spectrometer; current source; laser diode;
fLanguage
English
Publisher
ieee
Conference_Titel
Image and Signal Processing (CISP), 2010 3rd International Congress on
Conference_Location
Yantai
Print_ISBN
978-1-4244-6513-2
Type
conf
DOI
10.1109/CISP.2010.5646829
Filename
5646829
Link To Document